The Pt100/Pt1000 and thermocouple thermometer is a dual-input portable instrument designed for temperature measurement using two different sensor technologies: Pt100/Pt1000 RTD probes and thermocouples. It is suitable when the application requires either high-stability RTD sensors or thermocouples for extended temperature ranges and fast response times.
The instrument features one input for 3-wire or 4-wire Pt100 probes and 2-wire Pt1000 probes, with 8-pole connector and SICRAM module compatibility, plus one dedicated input for K, J, T, N and E thermocouples with standard polarized miniature connector. This configuration makes the instrument more flexible than standard Pt100 thermometers, allowing the most suitable probe type to be selected according to the application: immersion, penetration, surface or air measurements.
With Pt100/Pt1000 probes, the measuring range is -200 to +650 °C, while with thermocouples the range varies according to the connected type: K -200 to +1370 °C, J -100 to +750 °C, T -200 to +400 °C, N -200 to +1300 °C, E -200 to +750 °C. The resolution is 0.1 °C, with selectable units in °C and °F.
RTD probes equipped with SICRAM module technology are automatically recognized by the instrument and internally store calibration data. This allows safe and correct probe association, especially when different sensors are used for different applications.
The thermocouple input considerably extends the operating range. Pt100/Pt1000 RTD probes are generally preferred where stability, accuratezza and repeatable measurements are required over a wide range, while thermocouples are more suitable for fast response, lightweight probes, high-temperature applications or measurements in difficult-to-access areas.
The instrument includes RS232C output for real-time data transfer to PC or portable printers. Baud rate can be configured from 1200 to 38400 baud, and print interval can be immediate or menu-configurable. For USB connection to a PC, a dedicated USB/serial converter is required.
Functions include Max, Min and Avg, relative measurement REL, HOLD and selectable auto power-off. Its IP66 protection rating makes the instrument suitable for field use, laboratory work, maintenance and industrial inspections.
Pt100/Pt1000 RTD probes comply with IEC 60751, defining platinum sensor tolerance classes. Thermocouples comply with IEC 60584-1:2013, defining tolerance classes and operating ranges for thermocouple types.
Applications
- Temperature measurements with Pt100, Pt1000 and thermocouple probes
- Laboratory inspections, maintenance, production and testing
- Immersion, penetration, surface and air measurements
- Applications requiring both RTD probes and thermocouples in the same instrument
- High-temperature measurements with K or N thermocouples
- Fast-response inspections with thermocouples in difficult-to-access areas
- Real-time data transfer to PC or portable printers through RS232C
- Use with Pt100/Pt1000 probes according to IEC 60751 and thermocouples according to IEC 60584-1
FAQ – Pt100/Pt1000 and Thermocouple Thermometer
When should a Pt100/Pt1000 and thermocouple thermometer be selected?
It is suitable when a flexible instrument is required, capable of operating with both Pt100/Pt1000 RTD probes and thermocouples. It is useful when different applications require different sensor technologies depending on temperature range, response time or measuring conditions.
What is the difference compared to a Pt100-only thermometer?
A Pt100-only thermometer works exclusively with RTD probes. This model also supports K, J, T, N and E thermocouples, allowing measurements over wider temperature ranges and with sensors often more suitable for fast response or difficult measuring points.
Which thermocouples can it use?
It can operate with K, J, T, N and E thermocouples using standard polarized miniature connectors.
What is the measuring range with Pt100 and Pt1000 probes?
With Pt100 or Pt1000 probes the measuring range is -200 to +650 °C, depending on the connected probe.
What is the measuring range with K-type thermocouple?
With K-type thermocouple the instrument range reaches -200 to +1370 °C. The effective operating range also depends on the thermocouple used.
When is it better to use Pt100 and when a thermocouple?
Pt100 probes are preferable where stability and accuratezza are required in controlled measurements. Thermocouples are more suitable for high temperatures, fast response times, lightweight probes or difficult-to-access measuring points.
Does the instrument internally record data?
No. This version is not datalogger-enabled. It does however allow real-time transfer of measurements through RS232C output.
Can it be connected to a printer?
Yes. Through the RS232C interface it can be connected to a compatible portable printer using the dedicated cable.
Are probes included?
No. Pt100/Pt1000 probes, thermocouples and data transfer cables must be selected and ordered separately according to the application.
Fill out the form below to contact us.
"*" indicates required fields