{"id":35050,"date":"2025-10-27T18:18:38","date_gmt":"2025-10-27T17:18:38","guid":{"rendered":"https:\/\/www.samatools.it\/?post_type=product&#038;p=35050"},"modified":"2026-05-14T09:20:04","modified_gmt":"2026-05-14T07:20:04","slug":"thermocouple-pt100-thermometer-hd2178-1","status":"publish","type":"product","link":"https:\/\/www.samatools.it\/en\/product\/thermocouple-pt100-thermometer-hd2178-1\/","title":{"rendered":"Pt100\/Pt1000 and Thermocouple Thermometer &#8211; HD2178.1"},"content":{"rendered":"<p>The <strong>Pt100\/Pt1000 and thermocouple thermometer <\/strong>is a dual-input portable instrument designed for temperature measurement using two different sensor technologies: <strong>Pt100\/Pt1000 RTD probes<\/strong> and <strong>thermocouples<\/strong>. It is suitable when the application requires either high-stability RTD sensors or thermocouples for extended temperature ranges and fast response times.<\/p>\n<p>The instrument features one input for <strong>3-wire or 4-wire Pt100 probes and 2-wire Pt1000 probes<\/strong>, with 8-pole connector and SICRAM module compatibility, plus one dedicated input for <strong>K, J, T, N and E thermocouples<\/strong> with standard polarized miniature connector. This configuration makes the instrument more flexible than standard Pt100 thermometers, allowing the most suitable probe type to be selected according to the application: immersion, penetration, surface or air measurements.<\/p>\n<p>With Pt100\/Pt1000 probes, the measuring range is <strong>-200 to +650 \u00b0C<\/strong>, while with thermocouples the range varies according to the connected type: <strong>K -200 to +1370 \u00b0C, J -100 to +750 \u00b0C, T -200 to +400 \u00b0C, N -200 to +1300 \u00b0C, E -200 to +750 \u00b0C<\/strong>. The resolution is <strong>0.1 \u00b0C<\/strong>, with selectable units in \u00b0C and \u00b0F.<\/p>\n<p>RTD probes equipped with <strong>SICRAM module<\/strong> technology are automatically recognized by the instrument and internally store calibration data. This allows safe and correct probe association, especially when different sensors are used for different applications.<\/p>\n<p>The thermocouple input considerably extends the operating range. <strong>Pt100\/Pt1000 RTD probes<\/strong> are generally preferred where stability, accuratezza and repeatable measurements are required over a wide range, while <strong>thermocouples<\/strong> are more suitable for fast response, lightweight probes, high-temperature applications or measurements in difficult-to-access areas.<\/p>\n<p>The instrument includes <strong>RS232C output<\/strong> for real-time data transfer to PC or portable printers. Baud rate can be configured from <strong>1200 to 38400 baud<\/strong>, and print interval can be immediate or menu-configurable. For USB connection to a PC, a dedicated USB\/serial converter is required.<\/p>\n<p>Functions include <strong>Max, Min and Avg<\/strong>, relative measurement <strong>REL<\/strong>, <strong>HOLD<\/strong> and selectable auto power-off. Its <strong>IP66 protection rating<\/strong> makes the instrument suitable for field use, laboratory work, maintenance and industrial inspections.<\/p>\n<p>Pt100\/Pt1000 RTD probes comply with <strong>IEC 60751<\/strong>, defining platinum sensor tolerance classes. Thermocouples comply with <strong>IEC 60584-1:2013<\/strong>, defining tolerance classes and operating ranges for thermocouple types.<\/p>\n<h3>Applications<\/h3>\n<ul>\n<li>Temperature measurements with Pt100, Pt1000 and thermocouple probes<\/li>\n<li>Laboratory inspections, maintenance, production and testing<\/li>\n<li>Immersion, penetration, surface and air measurements<\/li>\n<li>Applications requiring both RTD probes and thermocouples in the same instrument<\/li>\n<li>High-temperature measurements with K or N thermocouples<\/li>\n<li>Fast-response inspections with thermocouples in difficult-to-access areas<\/li>\n<li>Real-time data transfer to PC or portable printers through RS232C<\/li>\n<li>Use with Pt100\/Pt1000 probes according to IEC 60751 and thermocouples according to IEC 60584-1<\/li>\n<\/ul>\n<h2>FAQ &#8211; Pt100\/Pt1000 and Thermocouple Thermometer<\/h2>\n<p><strong>When should a Pt100\/Pt1000 and thermocouple thermometer be selected?<\/strong><br \/>\nIt is suitable when a flexible instrument is required, capable of operating with both Pt100\/Pt1000 RTD probes and thermocouples. It is useful when different applications require different sensor technologies depending on temperature range, response time or measuring conditions.<\/p>\n<p><strong>What is the difference compared to a Pt100-only thermometer?<\/strong><br \/>\nA Pt100-only thermometer works exclusively with RTD probes. This model also supports K, J, T, N and E thermocouples, allowing measurements over wider temperature ranges and with sensors often more suitable for fast response or difficult measuring points.<\/p>\n<p><strong>Which thermocouples can it use?<\/strong><br \/>\nIt can operate with K, J, T, N and E thermocouples using standard polarized miniature connectors.<\/p>\n<p><strong>What is the measuring range with Pt100 and Pt1000 probes?<\/strong><br \/>\nWith Pt100 or Pt1000 probes the measuring range is -200 to +650 \u00b0C, depending on the connected probe.<\/p>\n<p><strong>What is the measuring range with K-type thermocouple?<\/strong><br \/>\nWith K-type thermocouple the instrument range reaches -200 to +1370 \u00b0C. The effective operating range also depends on the thermocouple used.<\/p>\n<p><strong>When is it better to use Pt100 and when a thermocouple?<\/strong><br \/>\nPt100 probes are preferable where stability and accuratezza are required in controlled measurements. Thermocouples are more suitable for high temperatures, fast response times, lightweight probes or difficult-to-access measuring points.<\/p>\n<p><strong>Does the instrument internally record data?<\/strong><br \/>\nNo. This version is not datalogger-enabled. It does however allow real-time transfer of measurements through RS232C output.<\/p>\n<p><strong>Can it be connected to a printer?<\/strong><br \/>\nYes. Through the RS232C interface it can be connected to a compatible portable printer using the dedicated cable.<\/p>\n<p><strong>Are probes included?<\/strong><br \/>\nNo. Pt100\/Pt1000 probes, thermocouples and data transfer cables must be selected and ordered separately according to the application.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Pt100\/Pt1000 and thermocouple thermometer is a dual-input portable instrument designed for temperature measurement using two different sensor technologies: Pt100\/Pt1000 RTD probes and thermocouples. It is suitable when the application requires either high-stability RTD sensors or thermocouples for extended temperature ranges and fast response times. The instrument features one input for 3-wire or 4-wire Pt100 [&hellip;]<\/p>\n","protected":false},"featured_media":34979,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[6472],"product_tag":[],"class_list":["post-35050","product","type-product","status-publish","has-post-thumbnail","product_cat-thermometers","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.samatools.it\/en\/wp-json\/wp\/v2\/product\/35050","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.samatools.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.samatools.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.samatools.it\/en\/wp-json\/wp\/v2\/media\/34979"}],"wp:attachment":[{"href":"https:\/\/www.samatools.it\/en\/wp-json\/wp\/v2\/media?parent=35050"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.samatools.it\/en\/wp-json\/wp\/v2\/product_brand?post=35050"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.samatools.it\/en\/wp-json\/wp\/v2\/product_cat?post=35050"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.samatools.it\/en\/wp-json\/wp\/v2\/product_tag?post=35050"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}