The two-channel data logger thermometer is designed to measure temperature at two points simultaneously using K-type thermocouple probes. It is suitable for checks where a single value is not sufficient, but two areas of the same component, two points in a system, two stages of a process, or the temperature of a surface relative to the surrounding environment need to be compared.
The two inputs allow two K-type probes to be connected at the same time and their respective values to be displayed. This configuration is useful, for example, for checks on components being heated, thermal uniformity checks, comparisons between different points on a production line, checks on machinery, ovens, tanks, piping or surfaces subject to temperature variations.
The thermometer also calculates differential temperature, namely the difference between the two temperatures measured by the channels. This function helps assess any variations between two measuring points and can be useful when the temperature distribution during a process needs to be checked or values measured in different areas of the same component need to be compared.
The two supplied K-type bead probes are suitable for general checks and measurements at points that are not immediately accessible. For specific applications, optional K-type probes can be selected for surface, immersion, penetration and air measurements, allowing the thermometer to be configured according to the material, measuring point geometry and required temperature range.
The integrated data logger makes it possible to record series of measurements in the internal memory, making the thermometer suitable for checks carried out over time, process inspections and orderly data collection. The recording function can be used to document temperature trends during tests, production checks, system inspections or comparisons between different operating conditions.
Cable and software are included. The software makes it possible to acquire measurements in real time, download recordings from the internal memory and display data in table and graph format. The data output allows connection to software for measurement data collection, improving traceability and reducing transcription errors in quality-control processes.
The Hold and Max/Min functions complete the checking capabilities, making it possible to keep a measured value displayed and recall the maximum and minimum temperatures recorded during the inspection.
When measuring a single point is sufficient and data do not need to be recorded over time, the single-channel K-type digital thermometer may be selected. The two-channel model is the suitable solution when comparison between two temperatures, data logging, internal memory and software for measurement management are required.
Calibration report available on request, to accompany the data logger thermometer with metrological documentation useful for internal checks and for monitoring its status over time.
Applications
- Simultaneous temperature measurement at two different points
- Differential temperature monitoring between components, surfaces or process areas
- Checks on machinery, systems, ovens, piping and tanks
- Surface temperature measurement using dedicated K-type probes
- Temperature monitoring of liquids using immersion probes
- Measurements inside materials or products using penetration probes
- Air temperature checks in production departments, technical areas and systems
- Measurement logging during tests, production checks and process inspections
- Real-time data acquisition and download to a PC using included software
FAQ – Two-channel data logger thermometer
What does a two-channel data logger thermometer measure?
The thermometer measures temperature using two K-type probes connected to the two inputs. It therefore makes it possible to measure temperature simultaneously at two different points.
Why choose a two-channel thermometer?
The two-channel configuration is useful when two temperatures need to be compared at the same time, for example on two surfaces, two points in a system, two areas of a component or two stages of the same process.
What is differential temperature used for?
Differential temperature indicates the difference between the values measured by the two probes. It is useful for checking any thermal variations between two points subject to the same inspection.
Which K-type probes can be used?
The thermometer can be used with K-type probes for surface, immersion, penetration and air measurements. The choice of probe depends on the material to be checked, the point to be reached and the required temperature range.
Are K-type probes included?
The thermometer is supplied with two K-type bead probes, suitable for general measurements and checks at points that are less easy to reach. Optional probes are also available for specific applications.
What does the integrated data logger do?
The data logger makes it possible to record series of measurements in the instrument’s internal memory. It is useful for collecting data during process checks, inspections over time and technical tests.
Is the software included?
Yes, cable and software are included. The software makes it possible to acquire measurements in real time, download recordings from the internal memory and display data in table and graph format.
What are the Hold and Max/Min functions used for?
The Hold function keeps the measured value displayed. The Max/Min functions make it possible to recall the maximum and minimum temperatures recorded during the inspection.
When should a single-channel K-type digital thermometer be selected?
When only one point needs to be measured and data do not need to be recorded over time, the single-channel K-type digital thermometer may be selected.
Is a calibration report available for the thermometer?
Yes, a calibration report is available on request.